NameModel WT-250 Shaker Body Water-cooled Electric Vibration Sharker Testing System
Rated thrust (sine):250kN
Rated thrust (random):250kN
Rated thrust (impact):500kN
Rated sinusoidal acceleration:980m/s²
Rated random acceleration:784m/s²
Vertical platform weight:1000kg
First-order resonance frequency response:1800Hz(±5)
Shaker body size (LWH):1955mm1450mm1135mm
Frequency range:5-2100Hz
Rated displacement p-p:76mm
Rated speed:2m/s
Quality of moving parts:150kg
Diameter of moving coil:Ф650mm

Product Description


  • Performance index of shaker body model WT-250

    Rated thrust (sine)

    250kN

    Frequency range

    5-2100Hz

    Rated thrust (random)

    250kN

    Rated displacement p-p

    76mm

    Rated thrust (impact)

    500kN

    Rated speed

    2m/s

    Rated sinusoidal acceleration

    980m/s2

    Quality of moving parts

    150kg

    Rated random acceleration

    784m/s2

    Diameter of moving coil

    Ф650mm

    Vertical platform weight

    10000kg

    Rated load

    2500kg

    First-order resonance frequency response

    1800Hz±5%

    Magnetic leakage

    1mT

    Shaker body size (L*W*H)

    1995mm*1450mm*1135mm

    Moving coil fixing screw

    Ф200-8*M12Ф400-8*M12

    Ф600-8*M12

    Performance index of power amplifier model SAP-250

     

    Rated output power

    250kVA

    Amplifier efficiency

    90%

    Signal-to-noise ratio

    ≥65dB

    Amplifier weight

    2560kg

    Dimensions (L*W*H)

    850mm*1650mm*1770mm



    Performance index of cooling unit model WU-2

    Internal circulating water (distilled water) flow rate

    80L/min

    Flow of external circulating water (tap water)

    160L/min

    Pressure of internal circulating water (distilled water)

    1MPa

    Pressure of external circulating water (tap water)

    0.25-0.4MPa

    Dimensions (L*W*H)

    850mm*550mm*1770mm

    Distilled water requirements

    Water hardness 30ppm, PH7-8

    Conductivity 1µS/cm

    Power requirements380V 50Hz Three-phase 340kVA;

    Environmental requirements: temperature 0-40, humidity 0-90%, no condensation

    Air source requirements: 0.6-0.8MPa

    The system connection cable comes standard with 10 meters, and can be customized if customers have special needs.

    251.jpg252.jpg253.jpg 

    Shaker body model WTS-250                          Power amplifier                  Cooling unit

     

    *Optional products: 1. The impact force is 2~3 times optional, the impact speed is 5m/s optional, and the sinusoidal speed is 3m/s optional; 2. The vibration can start from 1Hz for special needs; 3. It can be used with horizontal sliding table and expansion table; 4. It can be used with remote control and multi-integrated integrated control; 5. It can be used with a variety of accessories, controllers and sensors; 6. It can be used with pneumatic and electric mobile devices; 7. It can be used with auxiliary support devices.